2 × Taq Plus PCR Mastermix (Without Dye)
Cat.No:PC1250 Solarbio
Storage:Store at -20℃,1 year.
Appearance:Liquid
Qty:
Size:
{{cart_num}}
My Cart>
Molecular Biology >
PCR/qPCR >
Nucleic Acid Amplification Enzyme & Premix >
2 × Taq Plus PCR Mastermix (Without Dye)Storage:Store at -20℃,1 year.
Appearance:Liquid
Qty:
Size:
Name | 2×Taq Plus PCR MasterMix (Dye Free) |
Appearance | Liquid |
Storage | Store at -20℃,1 year. |
Unit | Piece |
Specification | 1ml 5*1ml |
Product Description:
The PCR MasterMix produced by Solarbio contains three enzymes (Taq, Pfu, Taq plus), each corresponding to two PCR Mastermixes (dye and dye free), a total of six PCR mastermixes.
Taq: The most efficient heat-resistant DNA polymerase with an amplification rate of about 1-2kb/min. The amplification base error rate is about 10-5. The product has A on the end and can be directly used for TA cloning.
Pfu: Currently the highest fidelity of heat-resistant DNA polymerase, base error rate is 10-6, but the amplification efficiency is lower than Taq enzyme, generally can very well amplify the fragment below 2kb. The amplification rate was about 500bp/min. The product is flat and must be added A before it can be used for TA cloning.
Taq Plus: An equal mixture of Taq and Pfu. Combined with high amplification efficiency and good fidelity. The amplification efficiency is higher than Pfu, and the fidelity is better than Taq. The amplification rate is about 1000bp/min. The product has A on the end and can be directly used for TA cloning.
The dye can be detected by electrophoresis directly after PCR MasterMix reaction. After the reaction of dye-free PCR MasterMix, the sample buffer was added for electrophoretic detection.
Note:Product information may be optimized and upgraded. Please refer to the actual label information for accuracy.
Remark:These protocols are for reference only. Solarbio does not independently validate these methods.
Note:
1. The products are all for scientific research use only. Do not use it for medical, clinical diagnosis or treatment, food and cosmetics, etc. Do not store them in ordinary residential areas.
2. For your safety and health, please wear laboratory clothes, disposable gloves and masks.
3. The experimental results may be affected by many factors, after-sale service is limited to the product itself and does not involve other compensation.
Sorry, there is no experimental images.
Sorry, there is no more information.
Hyperoside Attenuates Sepsis-Induced Acute Lung Injury (ALI) through Autophagy Regulation and Inflammation Suppression
Click to check >>Author:Jingyin Mai, Qingqing He, Yuting Liu, Yuting Hou
IF:4.6000
Publish_to:MEDIATORS OF INFLAMMATION
PMID:37545738